charming-sunshine
ดู Blog ทั้งหมด

Testing Transformer อีกสักครั้ง..

เขียนโดย charming-sunshine
Step-Down Autotransformer(Constant Input Voltage)
Lamp
Primary
 
Secondary
 
(W1 - W2)
W1
V1
A1
PF1
 
W2
V2
A2
PF2
 
Losses
0
0
220.0
0
0
 
0
110.3
0
-
 
0
1
42.5
220.0
0.205
0.94
 
33.8
109.6
0.308
1.00
 
8.7
2
75.5
220.0
0.3475
0.98
 
65.2
109.4
0.597
1.00
 
10.3
3
107.75
220.0
0.495
0.99
 
96.2
108.6
0.888
1.00
 
11.55
4
139
220.0
0.64
0.99
 
126.6
107.9
1.175
1.00
 
12.4
5
172.5
220.0
0.79
0.99
 
156.3
107.9
1.473
1.00
 
16.2
6
200
220.0
0.9275
0.99
 
185.2
106.2
1.748
1.00
 
14.8
7
232.5
220.0
1.075
0.99
 
219.2
105.7
2.05
1.00
 
13.3
At Full Load Condition:  h  =    94.27  %     Losses =  13.3  W
S1 =   236.5  VA   S2  = 216.685  VA
Voltage Regulation =  4.35%


Step-Up Autotransformer(Constant Input Voltage)

Lamp
Primary
Secondary
(W1 - W2)
W1
V1
A1
PF1
W2
V2
A2
PF2
Losses
0
10.075
110
0.173
0.52
0.0
220.6
0.001
-
10.075
1
105.5
110
0.98
0.99
94.5 
214.5
0.442
1.00
11
2
192
110
1.7925 
0.99
178.8 
210.3
0.851 
&